AMIS Analog Networking
585-300-512 Issue 7
May 1999
AUDIX Administration
3-26Implementation
3
3. Go through the following form fields by pressing the key, and change
any fields needed to implement the AMIS Analog Networking and/or
Message Delivery features:
a. Local/remote
This display-only field shows
r
after the remote machine is
administered.
b. Password
This field does not apply to AMIS analog networking or message
delivery (it is used for digital networking only).
c. Ext length (or extension length prior to R1V8)
The extension length depends on the feature you are administering.
Valid entries are the digits 3 through 10.
For an amisac connection type (AMIS casual or two-step
addressing), this field specifies how many digits entered by
subscribers for an AMIS address are actually dialed by the
local system. For example, if the extension length is “7”, the
local system dials the dial string (if any) followed by the last
seven digits of the number a subscriber enters as the AMIS
address to the remote voice mail system (
not
the remote
mailbox ID). The AMIS prefix is not dialed.
For an amisap connection type (AMIS pre-administered or
one-step addressing), this field specifies the number of
digits required to identify a remote mailbox ID (the extension
length typically matches the extension length of the remote
switch).
For a calld connection type (message delivery), this field
specifies how many digits entered by subscribers for a
message delivery address are actually dialed by the local
system. For example, if the extension length is “10”, the local
system dials the dial string (if any) followed by the last ten
digits of the number a subscriber enters as a message
delivery address.
d. Voiced name
This field indicates “n” for a new machine (a name for this machine
has not yet been recorded). This field is automatically set to “y”
when you record a name for this machine. To delete a name that
was previously recorded, set this field to “n”. (If you delete a name
using this form, you must re-record it to change the field back to
“y”.)
TAB